Quartus

Port of type <type> of ClockLock PLL <name> cannot feed more than <number> destination(s)


CAUSE: The specified port of the specified ClockLock PLL feeds more than the specified number of destinations permitted. The port can feed only the specified number of destinations.
ACTION: Modify the design so the port feeds no more than the specified number of destinations.

- PLDWorld -

 

Created by chm2web html help conversion utility.