Configuration failed


CAUSE 1:

You tried to configure a device with the ByteBlasterMV, ByteBlaster II, or MasterBlaster communications cable, but the Programmer did not successfully load the data into the device. This problem can be caused by:

  • Communications cables not securely connected

  • Incorrect device selected

  • No power to target system


ACTION: Make sure all cables are securely connected, select a different device, or check the power on the target system.
CAUSE 2: You tried to configure a device with the ByteBlasterMV, ByteBlaster II, or MasterBlaster communications cable, and you directed the device to use a user-supplied clock on the CLKUSR pin for initialization, but you did not supply a start-up clock for initialization of the CLKUSR pin. As a result, the data did not load successfully into the device.
ACTION: Make sure you have specified a start-up clock for initialization of the CLKUSR pin, or specify that the device not use a user-supplied clock on the CLKUSR pin for initialization.