CAUSE: | You set the State Machine Processing logic option to Minimal Bits; however, the logic of the specified state machine is too complex for the Logic Synthesizer to process it using the minimal number of bits. |
ACTION: | No action is required. The Logic Synthesizer processes the state machine using simple binary encoding. To avoid receiving this message in the future, try simplifying the logic of the state machine. |